TRI-PRO
RURAL
WATER DISINFECTION & TREATMENT |
|
MUNICIPAL / RURAL WATER SUPPLY
DISINFECTION SYSTEM
|
|
Most common problems
encountered in rural potable water supply is the presence of undesirable and
harmful elements in water which is being pumped to public distribution
directly without prior treatment.
PRIMETECH offers TRI-PRO
system with a whole sum technology based practical solution in a simplified
way for effective supply of potable water to common man in rural
environment.
|
|
UNDESIRABLE ELEMENTS
IN WATER |
EFFECT ON WATER &
COMMUNITY |
-
ONLY COMMON SALT AND AC POWER REQUIRED.
-
NOT DEPENDENT ON CHEMICALS
-
EASY TO OPERATE AND MAINTAIN
-
COST EFFECTIVE.
-
AVOIDS HAZARDS ASSOCIATED WITH
CHLORINE GAS WHICH REQUIRES ELABORATE SAFETY SYSTEM.
|
-
Diseases outbreak
-
Bad taste, red stain,
discoloured water
-
Health hazard, system
chock
-
Health hazard, system
chock
-
Health hazard
-
Bad odour
-
Presence makes water not suitable for consumption
|
|
Installation
of TRI-PRO systems in new or already established rural and
municipal water supply schemes at specific water consuming
give immediate solution to above problems. |
|
TRI-PRO
TREATMENT PROCESS |
CHLORINE DEMAND CHART |
-
Oxidation of soluble ferrous iron to insoluble ferric group
-
Oxidation of iron bacteria
-
Oxidation of manganese.
-
Oxidation of Hydrogen sulphide
-
Killing of all pathogens (bacteria and virus)
-
Removing all suspended matter.
-
Removal of all insoluble / precipitated / colloidal
substances.
-
Achieving and maintaining a chlorine residual level of 0.1
to 0.2 ppm.
|
Impurities |
Chlorine demand |
|
1 ppm - Iron |
1 ppm |
|
1 ppm - Manganese |
2 ppm |
|
1 ppm - Hydrogen
sulphide |
1.7 ppm |
|
1 ppm - BOD |
0.5 ppm |
|
TRI-PRO PROCESS
SCHEMATIC |
 |
|
TRI-PRO
SYSTEM SALIENT FEATURES |
-
On-site electro
chlorination for disinfection and oxidation of ferrous, Mn group
-
Effective process
through tank – mixing eductor.
-
On line cartridge filter
to reduce load to ultra filtration process.
-
Ultra filtration to
remove all colloidal iron, silica, TSS and turbidity.
-
System delivers treated
water with 0.1 to 0.2 ppm residual chlorine.
-
Self cleaning system
design, Hence no day to day maintenance.
-
Reliable auto operation with timer panel and solenoid valves, Hence
operation without any operator’s intervention.
-
High quality components
for long service life.
-
Pre-assembled,
pre-wired, pre-programmed and factory tested system.
-
No field installation
required.
-
Company supported AMC
for quarterly maintenance visit.
-
No recurring water
treatment cost as a system do not utilize any consumable.
-
The waste water from the
plant @ less than 100 – 120 litres per batch do not pose any threat as it
is sanitized already by chlorine in the process.
-
The system can handle
upto 10 batches per day, i.e. 10000 litres of pure and safe drinking water
to the nearby community.
|
|
TRI-PRO SYSTEM
DESCRIPTION |
|
The water to be treated (
1000 litres per batch) for human consumption is collected in the raw water
tank @ 1150 litres. The oxidation and disinfection process is initiated
through a state of art “ Selective Ion electrolysis” by a high-tech –
electrolyser. The required chlorine in the safe form of dilute sodium
hypochlorite is generated on-site using the chloride present in the water.
A low voltage DC power pack supplies required DC power for process.
The oxidation process is
enhanced by establishing a thorough and intimate mixing of chlorine and
water by an tank mixing eductor and water feed pump.
Chlorine generation and
tank mixing is carried out for an hour to give sufficient contact time for
the water to get disinfected.
The chlorination and tank
mixing is automatically stopped after a set duration by a fail safe timer
based control panel. The partially treated water is pumped through a
cartridge filter to remove major suspended solids and particles.
The pre filtered water is
passed through a ultra filtration module which employs the advanced “hallow
fibre cross flow filtration technology” to remove particles of size upto 0.1
micron. The final treatment process enables a near 100% removal of ferric
(precipitated iron, bacterias like Giardia, Cryptospordium, colliform, etc.
and viruses, turbidity and suspended solids).
The treated water with
a recommended residual chlorine level of 0.2 ppm is collected in a tank
built in the system for public distribution. |
|
SCHEME DRAWING |
 |
|
SV1, SV2, SV3, SV4, SV5
– SOLENOID VALVES |
|
 |
|
PLAN |
|
 |
|
ELEVATION |
|
TECHNICAL SPECIFICATION |
|
Model
|
Power supply
|
Treatment capacity
|
Process time
|
No. Of batches per day |
|
TRI-PRO Std |
230 V AC |
1000 lit/batch |
1 hour * |
8 – 10 |
|
* Treatment time depends
on the quantum presence of ferrous, BOD, Turbidity levels. |
|