STERIFLO OHT |
|
RURAL WATER SUPPLY
DISINFECTION SYSTEM ONLINE CHLORINE DOSING
OVER HEAD TANK
INSTALLATION UPTO 100000 LITRES CAPACITY
|
|
FLOW
DIAGRAM SCHEME DRAWING |
 |
|

World Health Organization
Geneva
Guidelines for
Drinking-Water Quality
SECOND EDITION
Volume 1
Recommendations |
6.3.4 Disinfection
Terminal disinfection of piped drinking-water supplies is of paramount
importance and is almost universal, as it is the final barrier to the
transmission of water borne bacterial and vital diseases.
Normal conditions of chlorination (i.e., a free residual chlorine of 0.5 mg
per litre,) |
|
|
|
DISINFECTION BY STERIFLO - OHT |
CHEMISTRY OF ELECTROLYSIS |
|
PRIMETECH’s STERIFLO - MODEL OHT Water Disinfection
System provides safe sterilized water to rural areas. The technology is
user-friendly and safe to operate.
An ideal situation would be to sterilize water at the spot of
pumping. i.e. at the discharge of the bore well or at the overhead tank supply
pipeline.
PRIMETECH provides a reliable Chloridose Generator to produce
Sodium Hypochlorite at site using common salt, single phase AC power supply
and water. A dosing pump is used to dose the CHLORINE solution for
Disinfection of drinking water.
To meet the requirement of rural water supply, STERIFLO - OHT
Models Rnbies economical disinfection of large quantities of water. The micro
organisms are killed by the disinfectant produced using only common salt,
power and water. The treatment meets the standards set by WHO for
disinfection of drinking water. |
When a direct current is passed through
electrodes immersed in a brine solution, Chlorine and sodium hydroxide are
liberated and it mixes with each other and forms sodium Hypochlorite.
|
|
 |
|
STERIFLO - OHT INSTALLATION |
|
 |
|
ADVANTAGES OF STERIFLO-OHT |
-
Only common salt and AC power is required.
-
Online chlorine generation and dosing.
-
Not dependent on chemicals.
-
Helps in ensuring tail end ppm of minimum 0.5 as per WHO
requirements, when water Distribution from the over Head tank is
delivered to the consumer in a short span of time.
-
Least attention is required by the operator.
-
Simple and easy maintenance procedure.
-
A
permanent solution to eliminate possible water borne diseases.
-
Eliminates problems associated with bleaching powder /Toxic Chlorine gas.
-
Avoids hazards associated with chlorine
Gas which requires Elaborate safety system.
-
Assured system quality, performance with
service back up for long Term operation.
-
Very
Cost Effective.
|
|
STERIFLO - OHT MODELS |
SEQUENCE OF OPERATION OF
STERIFLO - OHT |
|
STERIFLO- OHT Model (OVER HEAD TANK)
Steriflo disinfection units for drinking water supply schemes is available
in four standard models. Water distribution is considered as Litres/day
capacity @ 1 ppm Chlorine dosage.
|
STERIFLO SYSTEM MODEL |
CHLORINE DOSE ppm |
TREATMENT
CAPACITY LIT/DAY |
SALT GMS/DAY |
| 3L |
1 |
30,000 |
120 |
| 6L |
1 |
60,000 |
240 |
| 10L |
1 |
1,00,000 |
400 |
| 20L |
1 |
2,00,000 |
800 |
| 40L |
1 |
4,00,000 |
1600 |
STERIFLO OHT system doses a pre-measured
quantity of Sodium hypochlorite solution into the water supply.
OPERATION
Steriflo generates 7 to 10gpl concentration of sodium hypochlorite solution.
The solution is transferred to the dosing tank. From dosing tank the
solution is injected into the water main by dosing pump.
DOSING
As soon as the water flows in the distribution main. Steriflo injects
chorine Solution at preset value. Operator can observe the flow of solution
through the flow meter. The dosage can be adjusted to obtain the desired
chlorine residual level in ppm.
Water sample can be drawn after injection point and analyze for availability
of free residual chlorine in water by a test kit provided.
The system can be operated with least attention. Once it is preset for the
required dosage level, there is no need to adjust the flow every day. |
-
Add common salt of specified quantity in the
generator tank.
-
Fill specified level of water into the Chloridose
generator & ensure that salt is dissolved.
-
Immerse the Chloridose cell.
-
Switch on the power supply of the generator
-
Now the generator works for next 22 hours to produce the solution.
-
After 22 hours Switch off the power supply.
-
The Chloridose solution is ready for Dosing
-
Chloridose automatically injects solution in to the water supply main when
unit is started.
|
|
INSTALLATION |
To meet the requirement of safe Rural Drinking
water supply, PRIMETECH offers Steriflo OHT Models for economical disinfection of
drinking water supply. Micro organisms, bacteria and viruses are killed by
disinfectant (Chlorine) produced by Steriflo OHT using only common salt,
power and water. The treatment meets the Standards of WHO for disinfection
of drinking water.
Steriflo OHT model can be installed below the overhead tank or nearby. It
can be installed in open . The entire unit is housed in a lockable cubicle
for operation and safety.
The weatherproof construction of the model can withstand all weather
conditions. The installation is very simple and all the auxiliaries and
accessories are supplied along with the plant. It requires only joining of
the pipeline supply to the distribution main from the Overhead tank as shown
in the drawing.
|
|
COST OF CONSUMABLE FOR
DISINFECTION |
For example, to treat 1,00,000 litres per day,
select Model 10 L. It can meet 50,000 litres capacity Overhead tank which
can be filled and distributed two times a day. The cost of consumable is
only 600 gms of edible salt which will be less than Re.1.0 per day. Hence
the Steriflo OHT model is highly cost effective and ideal for rural water
supply schemes.
In remote places availability of chlorine gas in cylinder , bleaching powder
and Hypochlorite solution are difficult for regular supply to disinfect the
drinking water. In case of Steriflo, only common salt is the consumable
which is very easily available. |