Required suction lift in MWC – Go to nearest higher suction lift in the
performance table.
-
Estimate the back pressure in the system, refer the table at
nearest higher back pressure and motive horizontally to meet the nearest
higher / equal required suction flow and fix it.
-
Move vertically to select required motive pressure.
-
Move vertically down to select required motive flow.
-
Carry out above exercise in 2555 series first and subsequently with 2565 &
2575 series to select optimum ejector with least motive flow and motive
pressure requirement for the given suction flow and lift conditions.
-
Note down the ejector reference number in the table for identification .
- Go
to dimensions table of catalogue to collect data on dimension of ejector
corresponding to size.
-
Refer the ejector as “size-model-reference no”
Typical ejector reference
|
Size |
Model |
Reference |
|
1” |
E3011 |
2555120 |
-
Selection tips – 2555 Series – for lower back pressure range.
2565 Series – for medium back pressure range.
2575 Series for Higher back pressure range.
-
Performance data table refers to test conditions with motive water @ 27
deg.C and Specific gravity 1.0, Viscosity – 1CP.
-
Please write to us / fill up the enquiry form for varying – motive liquid
/ Specific gravity / Viscosity / Temperature. Our design team will
suggest a suitable model.
-
Material of construction selection depends on operating fluids corrosive
properties.
|