Home Page | About Us | Products & Services | Test Facilities | Contact Us | Feedback
Products and services
Catalogue
Application
Enquiry Form

Air Jet Eductor Form

DOC: 28KB

Air Jet Eductor

E400 Series

Primetech offers a range of MINI AIR JET EDUCTORS to cater to a numerous industrial applications.  These eductors are ideally suitable for places where only an Air motive source is available or an application where a motive liquid cannot be considered.

 

Principle of operation: When the compressed air is passed through the eductor motive nozzle, the pressure energy of air is converted to high velocity energy.  High velocity air passage through nozzle results in vacuum build up at the eductor suction inlet.   The high vacuum developed at the eductor suction inlet, enables drawal of suction liquid in to the eductor.  The sucked liquid is mixed with the motive air stream and the air + liquid mixture passes thro’ the venturi throat and diffuser.  At the venturi diffuser, the velocity energy is converted to pressure energy.

Application

  • Suction and clean up of liquid spill.

  • Pumping out & draining a sump.

  • Extracting liquid sample from process.

  • In house, test bench vacuum source

Eductor construction & Material of construction

 Air jet eductor is assembled out of machined components with threaded / male end connections (std. pipe threads BSP).  Various materials can be employed for the air jet eductor depending on the type & nature of liquids being pumped.

 

Various MOC available 

  • Steel

  • SS 304

  • SS 316

  • Monel

  • Hastalloy C

  • Titanium

  • PVC

  • Polypropylene

  • Teflon, etc.

Dimensions table – E 400

Model

Eductor Size mm

Dimension – mm

A

B

C

D

E

F

G

E400.25

6

25

30

50

80

3.2

6

6

E400.5

15

32

32

53

90

6

12

12

E400.75

20

42

95

80

120

12

20

20

E401.0

25

48

45

95

140

20

25

25

Performance data for a standard, 25 mm – E401 – Air jet eductor

  • 6 Kg/cm2(g) – Motive air pressure

  • Atmospheric discharge pressure

  • Suction fluid water @ 27 Ί C

  • Motive air flow rate – 150 Nm3/hr

Suction Lift – m

1.0

2.0

3.5

4.0

5.0

6.0

7.0

7.5

Suction flow LPH of Water @ 27ΊC 220 180 150 130 95 75 55 45

Air Jet Eductor Capacity Ratios

EDUCTOR SIZE 6 15 20 25
CAPACITY RATIO 0.06 0.25 0.56 1
Note: For your enquiry please fill in the questionnaire for us to Select a suitable air jet eductor.
Designed By eMuthuMadhavan